Blowerproof Airtightness Membrane - 10 Kg VCL

Rated 5.0 by 1 Happy Customer
(incl VAT) £139.86 £127.14
-10%
(excl VAT) £105.95
Send Me a Quote
Every Order Plants 1 Tree and Protects 10 Existing Ones
Est. Delivery: 2-3 Working days
Calculate Estimate Shipping Charges

Request a Quote

Our team is happy to fulfil custom orders, offer special bulk discounts you cannot get from the website. Please get in touch today to discuss your needs.

Spray or roll-on airtightness membrane by Blowerproof is an easy-to-use and durable airtightness solution and vapour control on entire walls, connections and service penetrations of a building. 

Airtightness membrane quickly adheres to most building surfaces like wood, mortar, PVC or even insulation. It perfectly covers any gaps, cracked or small holes on the building surface. It is also easy to apply to the corners or spaces that cannot be easily reached like those in the roof/wall or wall-floor connections.

Upon drying it forms a flexible, continuous and lasting membrane that protects your building from any water or air entry. It also acts as an intelligent vapour control layer. It protects your building from the harmful effects of radon rays. It is free of any VOC and harsh chemicals, so it is safe to use. Since it does not contain any organic- solvents, even the dried material can be discarded as non-hazardous waste.

Airtightness membrane by Blowerproof is very easy to use. Prepare the solution just when you are ready to use it. Simply apply it using a roll-on or spray it using an airless spray device onto the substrate. It is much better to use this liquid membrane than dealing with any paper-based vapour control layers where you have to tape or staple them whilst taking extra care to keep them from getting damaged.
 

Key Features:

  • A water-based airtightness membrane. VOC and chemical-free
  • Certified by BBA and Passive House Institute
  • Easy to apply. Not labour-intensive and allows for quicker applications.
  • Quickly adheres to many building surfaces including insulation, concrete and PVC.
  • Forms a flexible, durable and lasting air and vapour control layer upon drying.
  • Can be easily applied to hard-to-reach or awkward places.
  • Can be used for new builds and refurbishment projects
  • This airtightness membrane can be rendered, painted or plastered over.
  • Can also be used on moist surfaces

Application: 

Blowerproof airtightness membrane is best used on:

  • Connections: wall/wall, wall/floor, wall/ceiling
  • Service penetrations, curtain walls
  • Vapour control layer for entire walls
  • Insulation like Rockwool.

Airtightness membrane adheres perfectly to concrete, aluminium, stone, wood, metal, insulation, and EPDM.

Installation:

  • Clean the surface where you intend to apply the airtightness membrane with a vacuum cleaner to rid any loose materials, standing water etc.
  • Close any gaps more than 5mm deep using a gap-filling mortar.
  • Airtightness membrane can be applied on damp or moist surfaces.
  • Mix the Blowerproof liquid to a neat, homogeneous consistency with a handheld paddle mixer slowly.
  • Apply this airtightness membrane using an airless spray machine or a long-haired roller.
  • It can be applied in two layers if need be, only after the first layer has completely dried off.  The blue-coloured liquid turns black upon drying.
  • For complete installation guidance, please refer to the manufacturer's guidelines and datasheet. 
  • Pack Size: 10 Kg Tub
  • Colours Available: Blue and White
  • Spray or roll-on airtightness membrane.
  • Vapour control layer for walls and connections.
  • VOC-free and free of harsh chemicals.
  • Airtightness membrane allows quick adhesion to most building surfaces.
  • Quicker and less labour intensive.
  • BBA and Passive House Institute certified.
Product Type  Airtightness Membrane
Brand  Blowerproof
Pack Size  10Kg Tub
Colour  Blue (Black when dried), White
Material   Waterborne polymer paste 
Adheres to   bricks, blocks, concrete, stone, wood, metal, aluminium, insulation, EPDM
Density   +/- 1.2 kg/litre
Storage  1 year ( in unopened packaging )
Storage Temperature  Between 5*C and 20*C
Application Method  Spray or roll-on
Applied to   Connections, an entire wall, service penetrations

 

5.0
Average Rating
(1 Reviews)
Write Review
Order Quantity Delivery Charge (Excluding VAT)
1- 5 Tubs £8/Tub
6- 10 Tubs £50 - Pallet Charges
Pallet Charges are applicable for orders 

Lead Time: Lead time for stocked items is 5-7 working days 

Delivery: All orders are delivered through couriers. Delivery charges are calculated accordingly. If you have bulk requirements, please email us for a quotation

Receiving Delivery: We urge you to check the delivery properly for any damages as soon as you receive the order. Any damages must be mentioned in the delivery note before the driver leaves otherwise we will be unable to replace damaged goods.

If you are unsure, please call us.

Returns, Cancellations and refunds:

You are free to cancel your order before we send you an order confirmation email and get a full refund

Items ordered in excess: If you wish to return the items ordered in excess and claim a refund, please note that a restocking fee may be applicable. Please let us know if you wish to do so within 14 days from the date of delivery via email. You have to return the goods to us at the address that we will share in the email.

Damaged goods: We hence urge you to check for any damages in the insulation received before Please make sure you check the delivery, and if any part of it is damaged then you must mark this on the delivery note before the driver leaves otherwise we are unable to replace any damaged goods, if you are unsure then please call us before the driver leaves.

If the items are signed for without checking, we cannot replace/refund the insulation.

Customer Reviews

Our Customers Include

Brand
Brand
Brand
Brand
Brand
Brand
Brand
Brand
Blowerproof Airtightness Membrane - 10 Kg VCL

Guarantee unmatched airtightness and durability with Blowerproof Airtightness Membrane - 10 Kg VCL. This certified membrane offers permanent airtightness, intelligent vapour control, and a radon barrier. Achieve seamless finishes for joints, corners, and penetrations. It provides flexibility, continuity, and longevity in airtight coating. Application is simple with spray or roll-on methods, catering to different project needs. Compatible with various materials, it excels in sealing service penetrations like pipes and ducting for lasting airtightness. Significant long-term benefits include cost savings, reduced energy consumption, and improved indoor comfort. Embrace green construction with VOC-free, environmentally friendly features. Experience enhanced building performance with this efficient membrane.

Key Takeaways

  • Certified by BBA & Passive House Institute for airtightness, vapour control, & radon barrier.
  • Suitable for joints, corners, penetrations with plaster, ensuring seamless integration.
  • Long-term benefits include cost savings, energy efficiency, and improved indoor environment.
  • Compatible with various surfaces like blockwork, masonry, and concrete for durability.
  • Environmentally friendly with VOC-free composition, contributing to green building practices.

Key Features

Blowerproof Airtightness Membrane - 10 Kg VCL offers a range of key features that make it a top choice for construction projects. When it comes to durability, this membrane is certified as permanent airtightness, intelligent vapour control, and radon barrier by the BBA and the Passive House Institute. This means you can rely on it to withstand the test of time, reducing maintenance costs in the long run.

Moreover, the membrane prevents moisture migration into the applied surface with an Sd value between 20 and 30. This feature guarantees that your construction remains protected from the damaging effects of moisture infiltration, further enhancing its durability. Additionally, it allows excess humidity to escape while maintaining airtightness, creating a healthy and sustainable environment within your building.

Furthermore, the membrane is suitable for sealing joints, corners, and penetrations with plaster as the airtight layer, providing a seamless integration into your construction elements. Its flexibility, continuity, and permanent airtight coating make it a reliable choice for safeguarding the longevity of your project.

Application Methods

To achieve best results when applying the Blowerproof Airtightness Membrane, consider utilizing either a spray or roll-on method for a seamless finish. The spray application provides a quick and efficient way to cover large areas, ensuring an even coating for effective airtight sealing. On the other hand, the roll-on technique allows for more precision and control, perfect for detailed work or smaller surfaces. Both methods offer advantages depending on the project requirements, so choose the one that best suits your needs.

The spray application is ideal for covering extensive areas like walls and ceilings rapidly. It simplifies the process, making it suitable for larger projects where speed is essential. Alternatively, the roll-on technique is great for ensuring thorough coverage on specific spots that require extra attention. This method is precise and allows you to control the thickness of the membrane applied.

Whether you opt for the spray or roll-on method, you can achieve a professional and airtight finish with the Blowerproof Airtightness Membrane.

Surface Compatibility

When considering surface compatibility for the Blowerproof Airtightness Membrane, various construction materials such as blockwork, masonry, brickwork, concrete, and steel are supported. This membrane offers compatibility advantages by providing a flexible and continuous airtight coating on different surfaces. It is specifically designed to seal joints, corners, penetrations, and connections in construction projects, guaranteeing airtight connections for both new build and retrofit applications. The Blowerproof Airtightness Membrane excels in sealing service penetrations like pipes, cables, and ducting effectively.

Compatibility Advantages

Installation Challenges

Surface Preparation

Product Durability

Flexible and continuous airtight coating

Requires precise installation techniques

Surface must be clean and dry

Ensures long-lasting airtightness

Suitable for various construction materials

Properly sealing joints and corners can be intricate

Make sure no dust, debris, or moisture on the surface

Resistant to wear and tear over time

Easy to apply on different surfaces

Ensuring proper adhesion can be challenging

May require priming depending on the surface

Withstands changes in temperature and environmental conditions

Long-Term Benefits

Considering the surface compatibility advantages discussed previously, the Blowerproof Airtightness Membrane provides a range of long-term benefits that guarantee lasting airtight connections and superior performance in construction projects.

By using this membrane, you can achieve significant cost savings over time. The airtightness it creates helps in reducing energy consumption by maintaining a consistent indoor temperature. This leads to lower heating and cooling costs, making your building more energy-efficient.

Additionally, the Blowerproof Membrane ensures that your construction projects remain airtight for years to come, preventing air leakage and enhancing overall comfort. Its ability to prevent moisture migration and allow excess humidity to escape also contributes to a healthier indoor environment.

With these long-term benefits, incorporating the Blowerproof Airtightness Membrane into your construction projects not only saves you money but also improves energy efficiency and comfort, ensuring a lasting impact on your building's performance.

Environmental Impact

The environmental impact of the Blowerproof Airtightness Membrane is notably reduced due to its VOC-free composition and absence of harsh chemicals. By selecting this membrane for your construction projects, you're actively contributing to green building and sustainable construction practices. This membrane not only aids in creating a more energy-efficient building but also guarantees a healthier indoor environment by preventing moisture migration into surfaces. Certified by the BBA and the Passive House Institute, it meets the standards for sustainable building practices, making it a dependable choice for environmentally conscious builders like yourself.

Incorporating the Blowerproof Airtightness Membrane in your projects allows excess humidity to escape while maintaining a continuous and permanent airtight seal. This contributes to enhancing the building's thermal performance and reducing heat loss, further highlighting its positive impact on sustainable construction. By prioritizing products like the Blowerproof Airtightness Membrane, you're taking a step towards creating more environmentally friendly and efficient buildings.

Installation Tips

To achieve peak performance when installing the Blowerproof Airtightness Membrane, start by making certain the surface is clean, dry, and free from dust. Using a suitable spray or roller application method will help you achieve a uniform and consistent coverage. Make sure to apply the membrane in a continuous and seamless manner to create an effective airtight barrier.

Here are some installation tips to guide you:

  • Seal joints, corners, and penetrations meticulously for best performance.
  • Allow the recommended drying time for the membrane to fully cure and provide maximum airtightness.
  • Regular maintenance of the membrane will ensure long-term effectiveness and cost savings.

Frequently Asked Questions

Is a VCL Airtight?

Yes, a VCL contributes to airtightness testing by preventing air leakage, ensuring thermal performance. It helps maintain a cozy and comfortable indoor environment. So, when sealing joints and corners, a VCL plays an essential role in enhancing airtightness.

Is a Breather Membrane Airtight?

Breather membranes are not essential; they allow water vapor but block liquid water. It's important to consider ventilation strategies when using them. These membranes are designed differently from airtightness membranes like Blowerproof.

Add a Review

Your email address will not be published.

Request Site Visit

closeclose

Delivery Charges

closeclose
Order Quantity Delivery Charge (Excluding VAT)
1- 5 Tubs £8/Tub
6- 10 Tubs £50 - Pallet Charges
Pallet Charges are applicable for orders 

Request a Call back

closeclose

Request a Quote

closeclose