Novia Vapour Control Layer 1000 Gauge VCL is a high-performance, medium-grade, single-ply vapour control layer designed to provide a continuous air and moisture barrier in buildings.

The vapour barrier is made of a medium specification, virgin blown polyethene material, making it suitable for use within the walls of timber frame constructions, or where the control of the passage of water vapour is required.

Novia VCL conforms to BS EN 13984 specifications. It is CE Approved and CPR-compliant, manufactured to strict quality standards and designed to withstand the most challenging of building environments.

The Novia Vapour Control Layer 1000 Gauge VCL is easy to install and can be used in both commercial and domestic applications. We recommend using double-sided butyl tapes, and one of the foil or BOPP lap tapes to complete the installation. When used in combination with Novia breather membranes, the assembly gives an air-tight and vapour-resistant system.

Moreover, Novia 1000 vapour control system also performs as an air-leakage barrier. This helps to prevent heat loss by convection in a building, thereby saving energy. 

Made of 1000 Gauge (250 microns) thick polyethylene, gives Novia VCL superior strength and durability. The roll is supplied multi-folded in 4m x 25m and has a translucent green tint, which helps with the installation. 

Key Features:

  • High-performance polyethylene membrane
  • Heavy-duty 1000 Gauge (250 microns) thickness
  • Effectively prevents interstitial condensation
  • Provides a continuous air and moisture barrier
  • Easy to install, lightweight VCL Roll
  • Compatible with a wide range of insulation materials
  • Suitable for both timber frame constructions
  • Prevents damp and mould growth
  • Helps maintain a healthy indoor environment
  • Versatile and can be used in a variety of building applications.

Applications:

  • The Novia Vapour Control Layer 1000 Gauge VCL is for use as a vapour control layer within the walls of timber frame constructions.
  • It can also be used for floor and roof applications

  • One Vapour Control Layer covers 100m2
  • Superior Air-leakage barrier and vapour control layer 
  • Made of 1000 Gauge, single-ply Virgin-grade blown polythene material.
  • CE Approved and CPR-compliant, Conforms with BS EN 13984
  • Ideal for wall, roof and floor applications
  • This product is NON-returnable
Product Type  Vapour Control Layer
Brand  Novia
Length  25M
Width  4M
Roll Coverage  100 Sqm
Thickness  1000 Guage
Material  Virgin-grade blown polythene material
Weight  24 Kg
Moisture vapour Permeability 0.131 g/m2 *d
Tear Resistance  >102 N
Applications  For use on walls, roofs and floor

 

Order Value (Ex. VAT)  Delivery Charges (Ex. VAT)
Up to £125

 £20

£1250 - £303  £30
£303 - £616  £40
£616 - £961  £50
Above £961  Free

 

Returns And Refunds

  • You are free to cancel the order anytime before we send you an order confirmation email with the estimated delivery date.
  • Once confirmed and delivered, The product is NON-RETURNABLE. The product comes to you straight from the manufacturer. NO Returns accepted
  • We urge you to check the insulation for any damage before the driver returns. If the product you received is damaged, please contact us immediately.
  • For more information, please refer to our Return Policy

Our Customers Include

Brand
Brand
Brand
Brand
Brand
Brand
Brand
Brand
Novia Vapour Control Layer - 1000 Gauge VCL - 4M X 25M

Novia's 1000 Gauge Vapour Control Layer, which measures 4m x 25m, provides excellent moisture resistance. This VCL effectively controls the flow of water vapour, ensuring durability and energy efficiency in a range of construction projects. Made from virgin grade polythene, it has a thickness of 1000 gauge (250 microns). Each roll covers 100m2, creating a strong barrier against mould and rot. Whether used for walls, roofs, or floors, Novia VCL helps to create comfortable indoor spaces. With superior airtightness and durability, Novia's VCL is suitable for various applications. Its green tint makes it easier to fix accurately, representing a cost-effective investment that balances quality and affordability. Discover more about the benefits of Novia's VCL for your projects.

Key Points

  • Made from virgin grade polythene for high quality and durability
  • 1000 gauge/250 microns thickness guarantees dependable moisture resistance
  • Covers a generous area of 100m2, ideal for different construction projects
  • Green tint helps with accurate installation, ensuring effective vapour control
  • Promotes airtightness, energy efficiency, and long-lasting building durability

Features of Novia 1000 Gauge VCL

When considering the features of Novia 1000 Gauge VCL, you'll find it's crafted from virgin grade polythene to guarantee quality and reliability. This Vapour Control Layer boasts exceptional moisture resistance, ensuring that your structures are well-protected from water vapour.

The green tint of the VCL not only adds a touch of distinction but also serves a practical purpose by aiding in accurate fixing during installation, making the process smoother for you. With a thickness of 1000 gauge/250 microns, this VCL provides a robust barrier against water vapour passage, giving you peace of mind regarding the integrity of your constructions.

Each roll, measuring 4m x 25m, covers an extensive area of 100m2, offering you efficiency and convenience in your projects. Novia 1000 Gauge VCL truly stands out with its moisture resistance and distinctive green tint, making it a reliable choice for those who prioritise quality and functionality in their building materials.

Installation Guide for Novia VCL

To properly set up Novia VCL, ensure a minimum 150mm overlap for all joints to achieve effective sealing. When fitting Novia Vapour Control Layer, ensure it is securely fixed using appropriate fixings.

The translucent green tint of Novia 1000 VCL helps with accurate fixing during installation. To maintain airtightness, focus on properly sealing service entry points. Use suitable installation techniques to ensure the VCL functions at its best.

Pay close attention to sealing methods to prevent air leakage and maintain a controlled environment. By following these guidelines, you can achieve a successful installation of Novia VCL for various applications, including walls, roofs, and floors.

Advantages of Using Novia VCL

For peak building performance, integrating Novia VCL provides essential benefits in controlling water vapour and ensuring airtightness. When you select Novia VCL, you can enjoy the following advantages:

  1. VCL Efficiency: Novia 1000 VCL is designed to effectively regulate water vapour flow, maintaining ideal indoor air quality. By using Novia VCL, you can prevent moisture-related issues and support energy efficiency within your building, guaranteeing a comfortable and healthy environment for occupants.
  2. Longevity Advantages: Suitable for timber frame constructions, Novia VCL contributes to the longevity of your building. Its medium specification ensures dependable vapour control, enhancing durability and long-term performance. With Novia VCL, you can have peace of mind knowing that your building is well-protected against moisture damage, promoting structural integrity over time.
  3. Airtightness Assurance: By integrating Novia VCL, you can achieve a higher level of airtightness in your building, reducing the risk of air leakage and heat loss. This contributes to improved energy efficiency and overall comfort, creating a welcoming space for all who enter.

Comparison With Other VCL Products

Comparing Novia 1000 Vapour Control Layer with other VCL products reveals its unique advantages in thickness and quality, setting it apart as a reliable choice for building protection. In terms of performance, Novia 1000 falls between 500G and 1200G membranes, making it a medium specification vapour control layer that meets CE Approval standards. Its 1000 gauge / 250-micron thickness provides a robust barrier against air-leakage, particularly beneficial for timber frame constructions. The translucent green tint of Novia 1000 aids in precise installation, ensuring accurate fixing during the building process.

When considering cost analysis, Novia 1000 offers a balance between quality and affordability. While it may not be the cheapest option on the market, its durability and effectiveness make it a cost-effective investment in the long run. By choosing Novia 1000 Vapour Control Layer, you're opting for a product that prioritises both performance and value, contributing to the longevity and airtightness of your building.

Maintenance Tips for Novia 1000 Gauge VCL

Regularly inspect your Novia 1000 Gauge VCL for tears, punctures, or any signs of damage to ensure peak performance. To protect the longevity of your VCL, consider the following maintenance tips:

  1. Repair Techniques: Quickly deal with any tears or punctures using Novia-approved repair patches to maintain the VCL's effectiveness.
  2. Proper Cleaning: Clean the VCL surface with a gentle detergent and water solution as required to remove dirt and debris that could compromise its integrity.
  3. Sealing and Securing: Ensure all overlaps and joints are tightly sealed to preserve air-tightness, and fasten the edges with suitable fixings to prevent any movement that could cause damage.

By following these maintenance tips, you will not only prolong the lifespan of your Novia 1000 Gauge VCL but also ensure that it continues to offer reliable vapour control for your building. Remember, a well-maintained VCL is crucial for a well-protected structure.

Uses of Novia Vapour Control Layer

Novia Vapour Control Layer finds versatile applications in timber frame constructions and as a vital barrier against draughts, ensuring effective regulation of water vapour flow.

When used in building envelopes, this control layer plays an essential role in moisture control, preventing issues like mould and rot. By maintaining airtightness, Novia VCL improves the overall performance of insulation in walls, roofs, and floors, helping to create a comfortable and energy-efficient living space for you.

Its 1000 gauge thickness guarantees efficient water vapour management, safeguarding your home against potential damage caused by excess moisture. Proper installation, including secure fixing, correct overlaps, and sealed entry points, is necessary to maximise the benefits of Novia Vapour Control Layer.

Embrace the protection and peace of mind that Novia VCL brings to your building, knowing that it works tirelessly behind the scenes to maintain a healthy indoor environment for you and your loved ones.

Frequently Asked Questions

What is the difference between VCL and Vapour Barrier?

Understanding the difference between VCL and a vapour barrier is essential. VCLs manage moisture without fully blocking it, while vapour barriers prevent water vapour diffusion entirely. Both are key moisture prevention techniques in construction projects.

What is the Polythene Vapour Control Layer from Novia 1000 Gauge 100m² DIY Kit?

When working with Novia Vapour Control Layer in your 100m2 DIY kit, remember it's a 1000 gauge Polythene VCL. It's important to understand the difference between VCL and vapour barrier, as well as the importance with blockwork.

How thick should the vapour control layer be?

For optimal vapour control effectiveness and moisture prevention, ensure that your Vapour Control Layer (VCL) complies with the building regulations by being of an adequate thickness. Compare different thicknesses to find a balance between quality and performance to enhance airtightness and moisture control in buildings.

Do you need a Damp Proof Course with Blockwork?

For compatibility with blockwork, you need a VCL. It controls moisture and improves airtightness. Follow these tips for correct installation: seal gaps, overlap joints, and secure edges. Ensuring the integrity of the VCL is crucial for durability.

Summary

To summarise, the Novia 1000 Gauge VCL provides a reliable solution for controlling moisture in buildings. Its easy installation, durability, and effectiveness make it a popular choice for builders and contractors.

By using Novia VCL, you can ensure a dry environment, protecting your structure from possible harm.

Think about using Novia VCL for your upcoming project to see the advantages for yourself.

Add a Review

Your email address will not be published.

Request Site Visit

closeclose

Delivery Charges

closeclose
Order Value (Ex. VAT)  Delivery Charges (Ex. VAT)
Up to £125

 £20

£1250 - £303  £30
£303 - £616  £40
£616 - £961  £50
Above £961  Free

 

Request a Call back

closeclose

Request a Quote

closeclose